Installation of Accessories
This is the activation delay. For brine reclaim, set this to the same value that AUX2 OUT 
is set to be ON (last setting on AUX2). This allows AUX3 to turn on immediately after 
AUX2 turns off.
Set this value to the number of minutes needed for aux 3 to be activated. Refer to the 
brine reclaim manual, 01018946, for recommended settings.
This concludes setting the AUX OUT values for Brine Reclaim. Press the key until you return to the Main Menu.
SERVICE PHONE NUMBER 
If the Modem is not installed it is possible, in addition to displaying the error message, to display a message that 
reads “Call Culligan at: XXXXXXXXXX” where the telephone number XXXXXXXXXX can be programmed by the 
dealership (typically programmed to be the telephone number of the dealership).  This number is programmed 
under the menu: Main Menu / Accessories / Service Phone.
From the home screen, press the DOWN arrow to ACCESSORIES.  Press the CHECK 
MARK button.
Press the DOWN arrow to scroll to SERVICE PHONE. Press the CHECK MARK 
button at SERVICE PHONE.
Press the CHECK MARK button to change SERVICE PHONE # setting.   Press the 
UP or DOWN arrow to increase or decrease each digit of the SERVICE PHONE #.   
Press the CHECK MARK to move to the next digit.  Press the CHECK MARK when the 
correct SERVICE PHONE # is displayed.
EXTERNAL FILTER  
The unit can provide alarm feedback for a sediment or carbon filter installed upstream of the unit. The Auxiliary 
flow alarm can be used to monitor the flow through this filter.
To use this feature it is necessary to specify the total lifetime totalized flow of the auxiliary filter in either gallons or 
liters at Main Menu/Accessories/Down  Once set, it will begin to track the total gallons through the system flow 
meter. Once 
the total flow reaches the specified lifetime totalized flow, the system will display the error 
message “Change Auxiliary Filter” on the main display as well as the remote display and via the 
telephone modem if these secondary devices are used.
system ok
7:32 am 2-1-08
 > 4) accessories
 > 10) service phone
service phone 
#
>
system ok
7:32 am 2-1-08
Note: Once the auxiliary filter has been replaced, the auxiliary filter alarm must be reset by returning 
to the same menu: Main Menu / Accessories / Auxiliary Flow Alarm.
 
Installation of Accessories 
44
43
  CULLIGAN GLOBAL ELECTRONIC CONTROLLER
aux3 out
delay 0 mins
aux3 out
on 0 mins