Brivo Systems Inc. ACS300-1 Manual De Usuario
Brivo ACS300 Installation Manual
Page 6
© 2017 Brivo Systems LLC. All rights reserved.
Rev 1
Wiring Recommendations
Signal
Belden # or
Equivalent
AWG
Twisted
Pair
Conductor
Shielded?
Max
Length
RS-485 Comm, two wire
9841
24
Yes
Yes
4000 ft
Power (22 gauge)
5504FE
22
Yes
Yes
600 ft
Power (18 gauge)
6300FE
18
Yes
Yes
1500 ft
RJ45-Ethernet (CAN Bus)
N/A
Cat5
Yes
Yes
1500 ft
Fire Alarm Relay
6300FE
18
Yes
Yes
1500 ft
Request-to-Exit
5520FE/6300FE
22/18
Yes
Yes
1500 ft
Door Contact
5500FE
22
Yes
Yes
1500 ft
Transformer Block
6300FE
18
Yes
Yes
1500 ft
Molex Connector
N/A
22
Yes
No
1 ft
Earth ground
N/A
6
Yes
Yes
20 to 40 ft
Reader Option 1 (22 AWG)
5504FE
22
Yes
Yes
250 ft
Reader Option 2 (20 AWG)
5400FE
20
Yes
Yes
300 ft
Reader Option 3 (18 AWG)
6300FE
18
Yes
Yes
500 ft
Additional Resources
The following additional resources are available for the installer as well as the client.
• Panel Networking Admin Interface Guide
• Reader/Keypad Wiring Guide
• Brivo OnAir Quick Start Guide
• Brivo Cellular Network Router Configuration Guide
• Reader/Keypad Wiring Guide
• Brivo OnAir Quick Start Guide
• Brivo Cellular Network Router Configuration Guide
• Brivo OnSite Server Quick Start Guide
• Brivo OnSite Quick Start Guide
• Brivo OnSite Administrator’s Manual
• Technical Support: 1-866-BRIVO-4-U
• Brivo OnSite Quick Start Guide
• Brivo OnSite Administrator’s Manual
• Technical Support: 1-866-BRIVO-4-U
• www.brivo.com