Brivo Systems Inc. ACS300-1 Manual De Usuario

Descargar
Página de 23
Brivo ACS300 Installation Manual 
Page 7 
 
 
 
 
© 2017 Brivo Systems LLC. All rights reserved. 
Rev 1
 
 
Pre-Installation Procedures 
 
Before you begin installing the Brivo control panel, perform the following tasks to ensure a safe, speedy, 
and successful installation. 
Understand the function of the Brivo ACS300 control panel (A/E/S). 
The ACS300-E, ACS300-A, and ACS300-S are one or two (2) reader control panels with multiple 
access points. This control panel is considered a standalone system. The control board has up 
to two (2) readers on-board. 
The Brivo ACS300-E uses an on-board Ethernet interface to communicate via any TCP/IP 
networking technology that can be connected through a hub, router or switch, including Wi-Fi 
and satellite communications. It is an IP-enabled Access Control System that interacts with the 
Brivo OnAir cloud server via the Internet application Brivo OnAir. 
The Brivo ACS300-A is identical to the ACS300-E except that the ACS300-A communicates to a 
Brivo OnSite Server instead of the Brivo OnAir cloud server. 
The Brivo ACS300-S is identical to the ACS300-E except that the ACS300-S cannot 
communicate through the web. Instead, it is programmed through an on-board interface for data 
management. 
Understand Brivo ACS300 product compatibility. 
The ACS300 control panel is compatible with a large number of standard reader models 
including the following (UL tested for compatibility) reader models: HID600, Identiv 8110, HID 
RPK40, Allegion MTK15, AWID KP-6840, and OSDP reader 921PTPTEK00385. Brivo products 
are designed to accommodate the latest updates in Wiegand and OSDP using RS-485 reader 
formats. The ACS300 control board is compatible with Wiegand devices that transmit up to 255-
bit data and OSDP readers using RS-485. 
A current list of compatible readers and keypads is maintained on Brivo’s website at 
http://www.brivo.com. If you have a specific model of reader or keypad that is not listed on the 
Brivo website, please contact Technical Support at 1-866-BRIVO-4-U to determine 
compatibility. 
Verify that the client site is ready to support the installation. 
1.  Check with the IT department to ensure that the ACS300 version to be installed is 
compatible with the company’s local area network (LAN).  
a)  The ACS300 is equipped with a standard RJ-45 socket that accepts a CAT5 or 
CAT6 cable with an RJ-45 plug on any 10/100 Ethernet network. Physically 
connecting the panel is the same as plugging any computer or other device into 
the LAN. 
b)  Refer to the Panel Networking Admin Interface Guide (or in the case of the 
ACS300-S, the Brivo OnSite Administrator’s Manual) for instructions on 
connecting to the LAN. The Panel Networking Admin Interface Guide (or Brivo 
OnSite Administrator’s Manual) also contains a complete list of requirements 
regarding TCP/IP configuration parameters and information about security 
considerations. 
2.  Download the corresponding Quick Start Guide from the Brivo website and provide it to 
the Master Administrator. This document provides instructions for registering and 
configuring the control panel in the appropriate application.