MC-Series System Installation & Testing 
Scheduled and Unscheduled Maintenance 
RadioFrame Networks, Inc.
  
79 
Repair Action: 
Check preceding alarms as to the cause of the SPAM reset. Reseat 
SPAM, if problem persists, Replace chassis. 
7.4.4.44 
Network memory shortage 
ID:  
0x100a 
Service: iden 
Severity: critical 
Cause:  
Out of Memory 
System Reaction: 
System Reset 
Repair Action: 
Internal problem with the network memory pool. Replace chassis. 
7.4.4.45 
RB sync fail with APC 
ID:  
0x100b 
Service: iden 
Severity: minor 
Cause:  
Timing Problem 
System Reaction: 
RadioBlade will be re-synchronized. 
Repair Action: 
Formally (RF SLOT MISS).  This problem occurs when the Radio Blade 
fails to synchronize with the BPC+SPAM.  If the problem is happening on 
all or many RadioBlades, check connectivity to RBS or replace RBS. 
If problem is happening on only 1 RadioBlade in multiple RBSs, then replace AIC. If problem is 
happening on only 1 RadioBlade, then reseat or replace RadioBlade. 
7.4.4.46 
Invalid RB Slot 
ID:  
0x100c 
Service: iden 
Severity: minor 
Cause:  
Equipment Malfunction 
System Reaction: 
Reset RadioBlade 
Repair Action: 
Reseat RadioBlade. If problem still persists, replace RadioBlade or move 
to another slot. If problem still persists, replace RBS. 
7.4.4.47 
BR within sector short of RBs 
ID:  
0x100d 
Service: iden 
Severity: major