MC-Series High-Power System
Final Checkout and Commissioning
998--01 Rev X1
RadioFrame Networks, Inc.
CONFIDENTIAL AND PROPRIETARY 55
5 Select the iDEN Configuration link at the bottom of the System Configuration page.
On the iDEN Configuration page, make sure the configuration agrees with the site
datafill and also the RF cabling. The sector assignments must match the cabling inn
the back of the cabinet. All cab/pos values must be associated with the appropriate
sector. The MC-Series system will attempt to register all BRs with the cab/pos
values selected in this menu. An example configuration is shown in Figure 34. For
more information, refer to section 3.4 “iDEN Configuration”.
datafill and also the RF cabling. The sector assignments must match the cabling inn
the back of the cabinet. All cab/pos values must be associated with the appropriate
sector. The MC-Series system will attempt to register all BRs with the cab/pos
values selected in this menu. An example configuration is shown in Figure 34. For
more information, refer to section 3.4 “iDEN Configuration”.
Figure 34 iDEN Configuration Page
6 After iDEN configuration is updated (by clicking on Save Changes), a System Reset
is required. (Refer to section 8.2 “Performing a System Reset” if necessary.
7 Go to the Performance Monitoring page (section 6.2.3.1 “Local Performance
Monitoring”) and confirm that are BRs that were intended to be brought up are in
the UEA state. If there are BRs that are not active, select the
the UEA state. If there are BRs that are not active, select the
Alarms tab and
review the
Active Alarm Manager for any active alarms.
For more information, refer to section 7.5.3 “System Manager Alarms”.