Справочник Пользователя для RadioFrame Networks Inc MCSERIESHP10

Скачать
Страница из 131
MC-Series High-Power System 
 
Final Checkout and Commissioning 
998--01 Rev X1 
RadioFrame Networks, Inc. 
CONFIDENTIAL AND PROPRIETARY 55 
 
 
5  Select the iDEN Configuration link at the bottom of the System Configuration page. 
On the iDEN Configuration page, make sure the configuration agrees with the site 
datafill and also the RF cabling. The sector assignments must match the cabling inn 
the back of the cabinet. All cab/pos values must be associated with the appropriate 
sector. The MC-Series system will attempt to register all BRs with the cab/pos 
values selected in this menu. An example configuration is shown in Figure 34. For 
more information, refer to section 3.4 “iDEN Configuration”. 
Figure 34  iDEN Configuration Page 
 
6  After iDEN configuration is updated (by clicking on Save Changes), a System Reset 
is required. (Refer to section 8.2 “Performing a System Reset” if necessary. 
7  Go to the Performance Monitoring page (section 6.2.3.1 “Local Performance 
Monitoring”) and confirm that are BRs that were intended to be brought up are in 
the UEA state. If there are BRs that are not active, select the 
Alarms tab and 
review the 
Active Alarm Manager for any active alarms. 
For more information, refer to section 7.5.3 “System Manager Alarms”.