USER MANUAL FOR COMFLEX-6Q00 5W 
 
ENU STATUS: 1-0-1 
Copyright - refer to title page 
Page 32 
 
 
 
 
3.5 
EQUIPMENT CONNECTION  
3.5.1  GROUNDING CONNECTION 
 
 
 
3.5.2  MU GROUNDING CONNECTION 
Step 1: Connect the GND cable to the GND connector and the building EARTH. Recommended GND 
cable size is # 12 AWG. 
 
Step 2: Ensure the GND cable is connected to building GND. 
 
Backup PSU 
Grounding Connector
MU Rack Grounding 
Connector
 
Figure 27: MU Grounding (MU Rear Panel) 
 
 
3.5.3 
RU GROUNDING CONNECTION
 
Step  1:  Connect  one  side of  the  supplied  copper wire  GND  cable  to right  side  of  RU with  two  M6×10 
hexagon Screws (screws are provided). Connect the other side of the supplied copper wire GND cable to 
the building EARTH with two M6 screws (screws are not provided). 
 
Step 2: Connect one side of the supplied copper wire GND cable to RU with two M6×10 hexagon Screws 
(screws  are  provided).  Connect  the  other  side  of  the  supplied  copper  wire  GND  cable  to  the  building 
EARTH with two M6 screws (screws are not provided). 
 
Note: There are two GND ports on both sides of PSU, users can use one of them according to real 
situation. 
 
Step 3: Ensure all GND cables are well grounded to building GND. 
WARNING! 
This unit must always be grounded. Consult an appropriate electrical 
inspection authority or an electrician if you are uncertain that suitable 
grounding is available.
  
 
Do not connect power before grounding.