EQUIPMENT CONNECTION
3.5.1 GROUNDING CONNECTION
3.5.2 MU GROUNDING CONNECTION
Step 1: Connect the GND cable to the GND connector and the building EARTH. Recommended GND
cable size is # 12 AWG.
Step 2: Ensure the GND cable is connected to building GND.
cable size is # 12 AWG.
Step 2: Ensure the GND cable is connected to building GND.
Backup PSU
Grounding Connector
MU Rack Grounding
Connector
Figure 27: MU Grounding (MU Rear Panel)
3.5.3
RU GROUNDING CONNECTION
Step 1: Connect one side of the supplied copper wire GND cable to right side of RU with two M6×10
hexagon Screws (screws are provided). Connect the other side of the supplied copper wire GND cable to
the building EARTH with two M6 screws (screws are not provided).
Step 2: Connect one side of the supplied copper wire GND cable to RU with two M6×10 hexagon Screws
(screws are provided). Connect the other side of the supplied copper wire GND cable to the building
EARTH with two M6 screws (screws are not provided).
Note: There are two GND ports on both sides of PSU, users can use one of them according to real
situation.
Step 3: Ensure all GND cables are well grounded to building GND.
hexagon Screws (screws are provided). Connect the other side of the supplied copper wire GND cable to
the building EARTH with two M6 screws (screws are not provided).
Step 2: Connect one side of the supplied copper wire GND cable to RU with two M6×10 hexagon Screws
(screws are provided). Connect the other side of the supplied copper wire GND cable to the building
EARTH with two M6 screws (screws are not provided).
Note: There are two GND ports on both sides of PSU, users can use one of them according to real
situation.
Step 3: Ensure all GND cables are well grounded to building GND.
WARNING!
This unit must always be grounded. Consult an appropriate electrical
inspection authority or an electrician if you are uncertain that suitable
grounding is available.
Do not connect power before grounding.