RF Unit Management Screen 
 
 
 
Figure 32: RF Unit 
 
 
NOTE: There are three statuses for PA Service: NormalRecovery and Shutdown. If PA output power 
or reflected power exceeds the threshold, software will trigger Recovery:  
 
It will reset PA and then re-detect the PA output power and reflected power, if they are normal, the PA 
Service Status will turn to Normal, if PA output power or reflected power is still over the threshold, PA 
Service Status will turn to Recovery again. 
 
If PA output power or reflected power is still over the threshold after six times of PA Recovery, PA 
Service status will be Shutdown which will need to be reset manually. Reset at Management > PA 
Reset.