Comba Telecom Ltd. MBDA-200 Manuale Utente
USER MANUAL FOR MBDA-200
ENU STATUS : 1-0-0
Copyright - refer to title page
Page 36
RF Unit Management Screen
Figure 32: RF Unit
NOTE: There are three statuses for PA Service: Normal, Recovery and Shutdown. If PA output power
or reflected power exceeds the threshold, software will trigger Recovery:
or reflected power exceeds the threshold, software will trigger Recovery:
It will reset PA and then re-detect the PA output power and reflected power, if they are normal, the PA
Service Status will turn to Normal, if PA output power or reflected power is still over the threshold, PA
Service Status will turn to Recovery again.
Service Status will turn to Normal, if PA output power or reflected power is still over the threshold, PA
Service Status will turn to Recovery again.
If PA output power or reflected power is still over the threshold after six times of PA Recovery, PA
Service status will be Shutdown which will need to be reset manually. Reset at Management > PA
Reset.
Service status will be Shutdown which will need to be reset manually. Reset at Management > PA
Reset.