Comba Telecom Ltd. MU-6100 Manual De Usuario

Descargar
Página de 62
USER MANUAL FOR COMFLEX 6100 1W 
 
ENU STATUS : 1-0-0 
Copyright - refer to title page 
Page 33 
 
 
 
 
1
2
3
4
 
Figure 32:  
Pins Allocation for “EXT_ALM” Port for RU 
 
Table 7
: Pin Definition of “EXT_ALM” Port for RU 
Pin number 
Alarm definition 
EXT. Alarm 1 
GND 
EXT. Alarm 2 
GND 
 
Note: Users need to configure Ext Alm 1~2 on WEB GUI to realize External Alarm (Refer to Chapter 5).  
 
 
3.5.7  MU BTS ALARM CONNECTION 
The equipment alarms can be signaled to the BTS via voltage-free relay contacts. The voltage-free relay 
connections are connected to the DB-9 port 
“BTS_ALAM” located on the MU. The following figure and 
table show the pin allocation and definition.  
  
1
2
4
3
5
6
7
9
8
BTS_OPEN
BTS_CLOSE
BTS_ COM
 
Figure 33
: Pins Allocation for “BTS_ALM” Port 
 
Table 8
: Pin Definition of “BTS_ALM” Port
 
Pin Number 
Definition 
Description 
BTS_OPEN 
Connects to the open terminal of the voltage free relay. 
BTS_COM  
Connects to the common terminal of the voltage free relay. 
BTS_CLOSE 
Connects to the close terminal of the voltage free relay. 
4 ~ 9 
NC 
Reserved. 
 
 
3.5.8  CONNECT TO PC 
The local commissioning and management for MU and RU is achieved through connecting to the WEB 
base GUI. 
 
Connect MU to PC 
 
Connect MU 
“OMT” port (RJ45) to the RJ45 port of PC with supplied Ethernet cable to achieve local 
monitoring and management.  
 
End of Section