Comba Telecom Ltd. MU-6100 Manual De Usuario

Descargar
Página de 62
USER MANUAL FOR COMFLEX 6100 1W 
 
ENU STATUS : 1-0-0 
Copyright - refer to title page 
Page 34 
 
 
 
 
 
4  COMMISSIONING 
4.1 
PRE-COMMISSIONING TASKS 
After equipment installation, perform the following steps before equipment powering and commissioning, 
check that the expected voltage, current, and power levels do not violate any ratings. Double check all 
connections including ground before applying power. Do not manipulate circuits or make changes when 
power is applied: 
 
 
Visually inspect the power connection within the equipment. Ensure that all cables are correctly and 
securely connected, including power cables, grounding wires, RF cables and optical cables.  
 
Check grounding connection and verify that 
the ground resistance is less than 5Ω.
 
 
Connect the equipment to the PC.  
 
Power on MU and RU. 
 
Monitor the initialization of the MU and RU though the LEDs on the panel. Refer to detailed LEDs 
information in the next section. 
 
 
4.2 
 LED INDICATORS 
Diagnostic LEDs are located on the MU front panel and RU bottorm panel; each indicates the status of a 
particular function: 
 
Table 9: MU LED Indications 
LED Indicator 
Normal Status 
Indication 
PWR 
Steady green 
Power indicator. If LED is off, it indicates the 
system has no power.  
RUN 
Flashing green 
(1 time/sec) 
MU operation indicator. After initialization (1~2 
minutes), the LED should flash at once per sec. 
(When upgrade firmware, LED will flash rapidly)  
ALM 
OFF 
Alarm indicator. If LED is RED, there is an 
alarm. 
OP 
Steady green 
Located on Fiber Optical Unit (FOU), it is an 
indicator for receive optical power. If LED is off, 
it indicates the receiving optical power is less 
than -10dBm. 
 
Table 10: RU LED Indications 
LED Indicator 
Normal Status 
Indication 
PWR 
Steady green 
Power indicator. If LED is off, it indicates the 
system has no power. 
RUN 
Flashing green 
(1 time/sec) 
RU operation indicator. After initialization (1~2 
minutes), the LED will flash once per sec. (When 
upgrade firmware, LED will flash rapidly) 
ALM 
off 
Alarm indicator. If LED is RED, there is an alarm. 
OP 
Steady green 
Located on Fiber Optical Unit (FOU), it is an 
indicator of Receiving optical power. If LED is off, 
it indicates the receiving optical power is less 
than -10dBm.