power, so the total output power will be (input A+gain) + (inputB+gain)+
…+(inputN+gain). For example, if 
there are two 1900MHz bands acess to MU, each has 10dBm input power, the total output power of RU 
1900MHz will be 37dBm+37dBm=40dBm. 
 
For Multi-channel same band access, 800+850 (which share the same PA) access and 700 Uper C + 
LowerABC (also shared PA), they all will have power superposition. In this situation, users need to adjust 
system gain manually; otherwise, the output power will be higher than 32dBm which will trigger alarms 
(See Chapter 6 for details). 
 
Refer to the method below for the gain adjustment: 
Suppose a band with N independent inputs, each input signal power are all X dBm. Apparently, there 
exists the following relationship between input and output after finished auto communication on WEB GUI: 
X dBm + Gain = Rated output power, then the total output power for N channels access is X dBm + Gain 
+ 10*Log(N) = Rated output power  + 10*Log(N), so Users need to set 10*Log(N) RFU ATT on WEB GUI 
for each channel.  
 
 
 
 