6  ALARMS AND TROUBLESHOOTING 
6.1  ALARMS 
Table 14: MU Alarm List 
Alarm List 
Alarm Condition 
Over-Temperature 
Alarm 
 
Alarm when equipment temperature is higher than the threshold, otherwise 
normal; 
 
Alarm judgment period: 3 minutes by default; 
 
Alarm threshold : 80
℃ by default. 
Optical Tx Alarm 
 
Alarm when Optical Transmiting power is lower than the threshold, otherwise 
normal; 
 
Alarm judgment period: 3 minutes by default; 
 
Alarm threshold: -7dBm by default. 
Optical Rx Alarm 
 
Alarm when Optical received power is lower than the threshold, otherwise 
normal; 
 
Alarm judgment period: 3 minutes by default; 
 
Alarm threshold: -10dBm by default. 
DL Input Power 
Overload Alarm 
 
Alarm when DL input power is higher than the threshold, otherwise normal; 
 
Alarm judgment period: 3 minutes by default; 
 
Alarm threshold: 32dBm by default. 
 
Table 15: RU Alarm List 
Alarm List 
Alarm Condition 
External Alarm 
 
Alarm status when the external terminals have the same H/L level with alarm 
level, otherwise normal; 
 
Alarm period: 10s by default. 
Over-Temperature 
Alarm 
 
Alarm when equipment temperature is higher than the threshold, otherwise 
normal; 
 
Alarm judgment period: 3 minutes by default; 
 
Alarm threshold : 80
℃ by default. 
Optical Tx Alarm 
 
Alarm When optical transmiting power is lower than the threshold, otherwise 
normal; 
 
Alarm judgment period: 3 minutes by default; 
 
Alarm threshold: 0dBm by default. 
Optical Rx Alarm 
 
Alarm When optical receiving power is lower than the threshold, otherwise 
normal; 
 
Alarm judgment period: 3 minutes by default; 
 
Alarm threshold: -14dBm by default. 
PA Alarm 
 
Alarm when any one of the PA Current Alarm,PA Over-temperature Alarm, 
PA DL output power overload Alarm, Reflection Power Alarm happens, 
otherwise normal; 
 
Alarm judgment period: 3 minutes by default. 
DL Output 
Overload Alarm 
 
Alarm when the DL output power is higher than the threshold, otherwise 
normal; 
 
Alarm judgment period: 3 minutes by default; 
 
Alarm threshold: 32dBm for LRU, 39dBm for MRU. 
Shutdown Alarm 
 
Alarm when the PA status is off, otherwise normal; 
 
Alarm judgment period: 10s by default. 
LNA Alarm 
 
Alarm when LNA have problems, otherwise normal; 
 
Alarm judgment period: 3 minutes by default.