AP-228 Wireless Access Point
| Installation Guide
9
Figure 7  
Attaching the AP to the Mounting Bracket
Figure 8  
Completed Installation
Grounding the AP
The grounding must be completed before powering up the AP. The grounding wire should be #8 
AWG.
1. Peel the cover of one end of the grounding wire and place the bare grounding wire into the 
included copper lug, and press firmly with the crimping pliers.
2. Fasten the copper lug to the grounding hole on the AP with the included M4 x6 screw. 
Connecting the Ethernet Cable
To connect the Ethernet cable to the AP, perform the following steps using the cable glands that ships 
with your AP.
WARNING
Failure to use the included Ethernet cable glands can lead to connectivity and POE issues.