Mobiltex Data Ltd 03579 Manual De Usuario

Descargar
Página de 10
 
 
 
 
 
 
Figure 6 - OVPC2G Side View - Antenna Port 
 
5.3  Expansion Serial Port 
The expansion serial port is a logic-level serial port complete with additional user configurable I/O.  This port is not 
externally accessible and is intended for use with optional devices installed within the OVPC2G housing.  Contact 
Mobiltex for application guidance prior to utilizing this connector. 
6.  General use guidelines 
1.  The OVPC2G must only be used when installed within Mobiltex holster part number MOB-H7500SW-FX6. 
2.  Ensure that the MMCX connector is securely connected with the holster’s internal antenna feed cable prior to 
powering the device. 
3.  Ensure that the battery is fully charged prior to use.  In the event that the battery fails to charge, it cannot be 
serviced or replaced by the end-user.  Contact Mobiltex Data Ltd. for service information. 
4.  To turn on the OVPC2G, remove the OVPC2G from the holster and slide the switch to the “on” (right-most) 
position.  Re-install the OVPC2G in the holster prior to use. 
5.  The LED indicators will automatically turn-off during normal operation.  To momentarily turn-on these 
indicators, tilt the bottom of the holster above horizontal.  Hold the holster in this position until the LED 
indicators turn-on.  The LEDs will automatically turn-off again after a few moments to conserve battery power. 
6.  The OVPC2G has two modes of low-battery shutdown.  In the first mode, the device will commence an orderly 
software shutdown when the battery has reached a pre-determined low limit.  In the second mode, hardware 
circuitry inhibits start-up and operation of the device when the battery voltage is too low for proper operation. 
 
Once power is applied, use of the OVPC2G is determined by end-user application software. 
 
MOBILTEX DATA LTD. 
TITLE: 
Mobiltex OVPC2G Hardware User’s Manual 
Calgary, Alberta 
DOCUMENT NO.: 
OVPC2G-MAN-001 
SHEET: 
9 of 10 
REV: 
002