Brooks Automation Inc. LF60C Manual De Usuario

Descargar
Página de 171
Product Manual - RFID Reader LF60C SoliD
105
 
C h a p t e r   7
O p e r a t i o n
Parameter 44
(0x2C)
FixedMID
Defines the read, write and error behavior regarding the CarrierIDLength defined 
in SEMI E99-0303.
0
Dynamic CID length (to ensure compatibility with older versions).
MID length is variable for writing to the tag.
Reading up to the first non-visible ASCII character.
1
Fixed CID length (to meet the new standard revision).
Length of MID in the tag must be the same as the reader settings. If 
there is a non-visible ASCII character within the CID field, an error
 occurs.
Default: 1
Parameter 45
(0x2D)
MIDFormat
Defines the physical format of the MID data in the transponder memory. Affects 
the messages S18F9/F10 and S18F11/F12.
0
E99 standard format left aligned - meets the 
requirement of the SEMI standard E99
Default: 0
Examples: MID string is '123456789ABC'
Parameter 45 = '0':
Tag memory:
Output string: '123456789ABC'
Page 2
9
A
B
C
0x00
0x00
0x00
0x0
0
Memory address
15
14
13
12
11
10
9
8
Page 1
1
2
3
4
5
6
7
8
Memory address
7
6
5
4
3
2
1
0