Brooks Automation Inc. LF60C Manual De Usuario
Product Manual - RFID Reader LF60C SoliD
106
C h a p t e r 7
O p e r a t i o n
Parameter 98
(0x62)
Protocol change allowed
This parameter enables/disables the automatic change between the BROOKS
ASCII and SECS protocol. If protocol change is enabled, the reader detects the
protocol type on the communication port, and switches to the new protocol type.
The setting of parameter 98 will not reflect the protocol change by DIP switches
on power up reset (see chapter
ASCII and SECS protocol. If protocol change is enabled, the reader detects the
protocol type on the communication port, and switches to the new protocol type.
The setting of parameter 98 will not reflect the protocol change by DIP switches
on power up reset (see chapter
0
No protocol change is allowed
1
Protocol change is allowed
Default: (1) Protocol change is allowed
Parameter 99
(0x63)
Customer code
If the customer requires special parameter settings that deviate from the default
values, a customer code can be assigned by BROOKS to set several parameter
values via one parameter.
The following parameters are defined:
values, a customer code can be assigned by BROOKS to set several parameter
values via one parameter.
The following parameters are defined:
'00'
Sets the following parameters:
Reader complies with the last revisions of SEMI E99-0303
Reader complies with the last revisions of SEMI E99-0303
'03'
Sets the following parameter:
Reader complies with older reader versions before the revision of
SEMI E99-0303.
Reader complies with older reader versions before the revision of
SEMI E99-0303.
Parameter
Value
37
2
42
0
43
16
44
1
45
0
Parameter
Value
37
1
42
0
43
8
44
0
45
0