6.6 
Power supply specifications 
Table 2 shows the specifications of the AM Power Supply. 
Technical specifications 
 
Dimensions (L x W x H) 
227 x 108 x 71 mm 
Weight 
2.1 kg 
Input voltage,  frequency & current 
230VAC 50-60Hz 500mA  
or 
115VAC 50-60Hz 1A 
Mains inlet type 
Fused AC IEC with ON/OFF switch 
Mains lead 
Euro Schuko to IEC, 1.5m length 
Output 
32.5VDC 1.6A + synchronization signal 
Output cable 
3x1mm
2
, fixed, 5m length. This cable can be 
extended  to  15m  using  a  3x1mm
2
  cable  or 
thicker. 
Temperature range 
– 50
o
External fuse 
Replace when changing mains voltage! 
230VAC 
– 1A slow 
115VAC 
– 2A slow 
Table 2: AM Power supply specifications 
6.7 
Switching to a different mains voltage 
The power supply supports 2 mains voltages; 230VAC (default setting) and 115VAC. 
By default the power supply is set to 230VAC mains input, but if required, the mains input 
can be switched to 115VAC. Follow the next steps to switch to a different mains voltage: 
1.  Disconnect from mains power and carefully open the power supply housing 
2.  Locate the internal switch and switch it to the required position 
3.  Replace the external fuse with the correct value (see Table 2) 
4.  Carefully close the power supply housing 
6.8 
Power supply restrictions 
This  power  supply  has  the  following  restrictions  which  must  be  respected  carefully  in 
order to warrant the safety of the product and user: 
 
Only to be used in combination with AM systems 
 
For indoor use only 
 
Disconnect from mains power before opening the housing 
 
Do not cover the ventilation holes of the housing