General 
Troubleshooting 
 
Is the PHMU placed 3 to 6 feet off the floor on a stable, nonmetallic surface?  
Is the phone line that is attached to the PHMU in good visible working order? We 
provide new phone lines with each PHMU; please utilize the phone lines we 
provide.   
Is the phone line fully inserted into the phone jack & PHMU?  
In order to check the PHMU, attach a telephone handset to the spare socket in 
the rear of the PHMU…then generate an event by unplugging the unit from both 
power and telephone for approx 2 minutes, then reconnect. Pause for 15 
seconds and lift the telephone handset. It should be possible to hear the unit 
dialing in to report the events.  
Wait 5 minutes, then phone the monitoring center and confirm that the events 
have been received and confirm the correct equipment serial numbers have 
been assigned  
Are you cutting the G4S Justice Services fiber optic band with the tools 
provided? Please do NOT fit the fiber optic band by cutting with standard 
scissors or wire cutters the cut may not be even (might bend the fibers) and 
could result in intermittent band tampers.  
If enters and leaves occur only at night, review with the participant the possible 
causes of interference  
Are you confirming proper range by conducting the Range Test?  
Troubleshooting Band 
Tampering Issues  
 
Band tampering can be checked at the office or in the field by performing the 
following sequence of steps:  
1.  First, remove the PTX by cutting the PTX Band. Turn the PTX over and 
inspect the pin barbs through the window.  If the pin barbs are broken, 
tampering has occurred.    
2.  Perform a visual inspection for scratches and any other sign of tampering.  
Damage to the PTX and/or Band are indicators of tamper.  
3.  Remove the PTX Band and check the cut. The cut must be straight for 
optimal performance of the light transmissions thru the fiber optics.    
4.  Check that the optical windows inside the PTX housing are clean.  
Tip: We recommend a thin cotton swab dipped in rubbing alcohol to clean 
the window found inside the PTX housing. 
NOTE: If participant equipment is replaced, the serial numbers assigned to the participant must be 
changed in the Monitoring System.