Sea Air and Land Communications 1286 Manual De Usuario

Descargar
Página de 8
SALCOM 12-86-0000 Keyring Paging Transmitter 
Issue 1286000UA 0210
Sea Air and Land Communications Ltd
Page 2
SERIAL PROGRAMMING
In order to program 12-86-0000 programming software should be downloaded from the Salcom website
(www.salcom.co.nz). 
A Salcom 12-47 programming lead is required to program the 12-86 transmitters (same lead used to
program the 11-85 transmitters), together with a 4 pin header.  This may be purchased separately.  The
12-47 programming lead requires the availability of a PC with a serial port, running windows XP.
Connect the 12-47 as shown below, with the dot on the 12-47 socket (circled in yellow in the photograph
below) towards the center of the PCB (mating with the square pad).
The 12-86 Programming Software allows the transmitter frequency and button messages to be set.
1
Press “Connect”.  The red LED will light, as a message is transmitted - this occurs when entering
program mode.  After the message has been sent, the green LED will light for approximately 1
second (visible on same side as buttons).  The status at the bottom of the 12-86 PSD will indicate
if successfully connected.
2
Press “Read”.  The current configuration is read from the 12-86.
3
Make any required changes.
4
Press the “Program” button.
5
Press “Disconnect”, then remove programming lead.
General Configuration 
Button Messages: Select the button to view the message, RIC and beep level assigned to that button.
New button settings can be entered, but will not be written until the program button is pressed.  The
program button only needs to be pressed after all button details have been populated.
SALCOM 12-86-0000 Keyring Paging Transmitter 
Issue 1286000UA 0210
Sea Air and Land Communications Ltd
Page 3
Frequency: The transmit frequency between 440 and 470MHz to be set using 25kHz channel spacing.
Pager Type: If set to “alphanumeric”, then any message can be set into the message box, and can only
be used with pagers that support alphanumeric messages.  When “numeric” is set then only
0,1,2,3,4,5,6,7,8,9,0,[,],-,E and U characters can be used.  Tone only pagers are supported by leaving
the message box empty.
Beep Level: Pager beep priority set - 1 highest, 4 lowest.
RIC Code: Pager ID.  Valid codes are 0000008 to 2000000