Sea Air and Land Communications 1286 Manual De Usuario

Descargar
Página de 8
SALCOM 12-86-0000 Keyring Paging Transmitter 
Issue 1286000UA 0210
Sea Air and Land Communications Ltd
Page 4
VISUAL PROGRAMMING
Using the same programming software as the serial programming method described above the 12-86-
0000 can be programmed using an windows XP computer with an LCD monitor. In this mode, the data
is transmitted to the transmitter by flashing the screen from white to black as can be seen in the
photographs below.
This method is slower than the serial method and only programs a single button at a time, but does not
require the transmitter to be opened or the user to possess a serial programming lead. Visual
programming will only work well in areas without large levels of ambient light and using LCD monitors
with sufficient brightness and contrast, although typical monitor settings are usually fine.  This method
will not work using CRT monitors.  
The 12-86 should be held as still as possible during the entire programming sequence.
In order to use the visual programming interface it must be first selected from the options menu.  The
feature must be enabled first from the  “Options->Config” item and the “Programming Mode” set to either
“Light”, or “Serial”. 
Programming Instructions:
1. 
Hold the 12-86 with the label side facing the screen at a distance of approximately 5 cm.
2. 
Press and hold any button.  The red LED will light as a message is transmitted, and then a green
LED will light (12-86 is now in program mode).  When the green LED lights, release the button.
3. 
Press “Connect”.  Once the green LED on the 12-86 flashes rapidly then stays on, press “Program”
(within 2 seconds) to begin programming. 
4. 
The green LED will flash once a second while programming.  When programming is complete,  both
the red and green LED will light together to indicate that programming was successful.  The red
LED will flash if programming was unsuccessful.
5. 
Repeat steps 2-4 for all other buttons, or if a previous programming attempt failed.
6.
To program the frequency check ‘Program Freq’ and repeat steps 1-4. 
NOTE: Numeric messages can be programmed in half the time as the same length alphanumeric
message
SALCOM 12-86-0000 Keyring Paging Transmitter 
Issue 1286000UA 0210
Sea Air and Land Communications Ltd
Page 5
SPECIFICATION
RF Frequency
UHF: 440-470MHz Synthesized.
Dimensions.
61mm x 31mm x 6mm. 
Supply Voltage
3 volt CR2032 button cell. 
Power Consumption
Sleep:100nA Transmit:45mA
Battery Life
Approx 1000 transmissions.  Approx 10 years
standby.
Temperature limits
-10 to +55deg, -30 to +60 on request.
Environmental protection
Needs  protection from weather and should be
mounted in an enclosure.  When used without an
enclosure the unit can be damaged by ESD.  
Channel Spacing
25kHz
Output Power
-5dBm
Modulation
Carrier FSK with NRZ data
Deviation
+/-4.5kHz
Transmit Duty Cycle
Up to 20%, 30 seconds continuous
Baud Rate
512 Baud
Type Approvals
AS/NZS 4769.1:2000  and EN 300 224-2.  Tested
to and meets FCC Part 90.
Aerial Integrated 
PCB 
BATTERY REPLACEMENT
Care must be taken when replacing the CR2032 coin cell.  The battery must be fitted with the ‘+’ up and
the ‘-’ touching the PCB.  Incorrect battery installation will rapidly discharge the coin cell, and may
damage the transmitter.
After battery replacement, test that the 12-86 is functional by sending a test message and verifying the
red LED lights.   If the unit fails to operate, remove battery, confirm correct battery orientation and
reinsert.