The TX10K  can be configured even while it is installed (but not 
rotating) using the RM10K Remote Control.  The TX10K  has 
sixteen RF Channel settings and six Gain settings (500, 1000, 
2000, 4000, 8000, and 16000).  It can send low and high 
reference signals to the RX10K: internal precision shunt resistors 
simulate strain values that can be used to check calibration (refer 
to Appendix A for specifications). 
 
NOTE: Make certain the Infrared Receiver lens remains 
unobstructed so that data can be received from the RM10K 
Remote Control.   
 
Status Indicator Light 
When the TX10K  is powered up  and done initializing, it is in 
normal operating mode (transmitting actual data from the sensor) 
and the Status Indicator is on solid.  An error is indicated when the 
light is flashing, flickering or off as described below.   
 
Indication 
 
 
TX10K Status 
Off continuously 
No power applied; power polarity 
is reversed; battery is dead; or the 
transmitter is in Standby mode. 
 
One flash off for ½ second 
A Gain or Channel command has 
been received from the RM10K 
Remote Control. 
 
Another flash off for ½ second  The Gain or Channel command 
has been carried out. 
 
NOTE: If there is only one flash 
when changing Gain or Channel, 
then the high or low limit has 
been reached and cannot change 
any further in that direction.