Binsfeld Engineering Inc TX10K-LP Manual De Usuario

Descargar
Página de 44
- 18 - 
 
connections to the TX10K  terminals.  Secure loose cable to 
shaft. 
5.  Connect Receiver Antenna to Antenna connector on the rear 
panel of the RX10K Receiver.  Position magnetic-mount 
antenna with element installed near the TX10K, typically within 
10 feet (3 meters). 
6.  Insert connector on AC/DC adapter into Power Input  jack on 
the RX10K rear panel.  Plug adapter into appropriate AC 
power source (i.e., wall socket).  Flip the RX10K power switch 
to On while holding down the ADJUST 
▲ key.   
NOTE: This resets the RX10K parameters to their default 
settings.  Simply turn On without holding any keys if previously 
set parameter configurations are desired. 
7.  Turn on the TX10K with the RM10K (if needed).  Confirm that 
Status Indicator light is on solid.  Slowly scroll through each 
RX10K channel until it matches TX10K  channel setting (top 
line will quit flashing and bottom line will show the RF signal 
strength).  Change both units to desired channel and verify 
adequate signal strength.  If possible, rotate the TX10K 
through complete range of motion to verify strong signal 
reception in all orientations. 
8.  Scroll RX10K display to Gain parameter screen.  Use the 
RM10K to configure the Transmitter Gain to the appropriate 
level. 
9.  Scroll RX10K display to Input AutoZero parameter screen.  
Apply AutoZero with no load on the shaft to zero-out any initial 
gage offset.  Press and hold ADJUST 
▲  key for 2 seconds 
until bottom line reads “Input AutoZero: On”.  AutoZero can be 
reset by turning off and then on again. 
NOTE: Once AutoZero is activated, the initial gage offset is 
subtracted from the output, which has a maximum range of 
±12 V.  The extra ±2 V overhead above and below Full Scale 
(±10 V) is provided to help minimize this reduction in range.  
For example, if the initial offset is 1.6 V, then the maximum 
output of the system will be 10.4 V after AutoZero is set.  This 