connections to the TX10K terminals. Secure loose cable to
shaft.
shaft.
5. Connect Receiver Antenna to Antenna connector on the rear
panel of the RX10K Receiver. Position magnetic-mount
antenna with element installed near the TX10K, typically within
10 feet (3 meters).
antenna with element installed near the TX10K, typically within
10 feet (3 meters).
6. Insert connector on AC/DC adapter into Power Input jack on
the RX10K rear panel. Plug adapter into appropriate AC
power source (i.e., wall socket). Flip the RX10K power switch
to On while holding down the ADJUST
power source (i.e., wall socket). Flip the RX10K power switch
to On while holding down the ADJUST
▲ key.
NOTE: This resets the RX10K parameters to their default
settings. Simply turn On without holding any keys if previously
set parameter configurations are desired.
settings. Simply turn On without holding any keys if previously
set parameter configurations are desired.
7. Turn on the TX10K with the RM10K (if needed). Confirm that
Status Indicator light is on solid. Slowly scroll through each
RX10K channel until it matches TX10K channel setting (top
line will quit flashing and bottom line will show the RF signal
strength). Change both units to desired channel and verify
adequate signal strength. If possible, rotate the TX10K
through complete range of motion to verify strong signal
reception in all orientations.
RX10K channel until it matches TX10K channel setting (top
line will quit flashing and bottom line will show the RF signal
strength). Change both units to desired channel and verify
adequate signal strength. If possible, rotate the TX10K
through complete range of motion to verify strong signal
reception in all orientations.
8. Scroll RX10K display to Gain parameter screen. Use the
RM10K to configure the Transmitter Gain to the appropriate
level.
level.
9. Scroll RX10K display to Input AutoZero parameter screen.
Apply AutoZero with no load on the shaft to zero-out any initial
gage offset. Press and hold ADJUST
gage offset. Press and hold ADJUST
▲ key for 2 seconds
until bottom line reads “Input AutoZero: On”. AutoZero can be
reset by turning off and then on again.
reset by turning off and then on again.
NOTE: Once AutoZero is activated, the initial gage offset is
subtracted from the output, which has a maximum range of
±12 V. The extra ±2 V overhead above and below Full Scale
(±10 V) is provided to help minimize this reduction in range.
For example, if the initial offset is 1.6 V, then the maximum
output of the system will be 10.4 V after AutoZero is set. This
still allows for strain measurement up to Full Scale.
subtracted from the output, which has a maximum range of
±12 V. The extra ±2 V overhead above and below Full Scale
(±10 V) is provided to help minimize this reduction in range.
For example, if the initial offset is 1.6 V, then the maximum
output of the system will be 10.4 V after AutoZero is set. This
still allows for strain measurement up to Full Scale.