Binsfeld Engineering Inc TX10K-LP Manual De Usuario
- 20 -
desired channel and verify adequate signal strength. (To
configure TX10K settings, use the RM10K Remote Control.)
configure TX10K settings, use the RM10K Remote Control.)
5. Scroll RX10K display to Gain parameter screen. Use the
RM10K to configure the Transmitter Gain to 4000 (“Gain
T:04000 S:04000”).
T:04000 S:04000”).
6. Scroll RX10K display to Input AutoZero parameter screen.
Apply AutoZero with BS900 in center or zero (0) position.
Press and hold ADJUST
Press and hold ADJUST
▲ key for 2 seconds until bottom line
reads “Input AutoZero: On”.
7. Switch BS900 to the positive (+) position. RX10K output
should be close to +2V (“+02000”) and the bar graph indicator
should move one segment to the right of zero (“0”).
should move one segment to the right of zero (“0”).
8. Switch BS900 to the negative (–) position. RX10K output
should be close to -2V (“-02000”) and the bar graph indicator
should move one segment to the left of zero (“0”).
should move one segment to the left of zero (“0”).
NOTE: The BS900 Bridge Simulator is not a calibrated
reference. Its purpose is to provide a full bridge circuit to the
TX10K to verify functionality and assist in troubleshooting.
reference. Its purpose is to provide a full bridge circuit to the
TX10K to verify functionality and assist in troubleshooting.
9. Use the RM10K to command the TX10K to transmit
REFERENCE 1. RX10K output should be close to +2V
(“+02000”) and the bar graph indicator should move one
segment to the right of zero (“0”) for a duration of 5 seconds.