Applied Concepts                                            011-0131-00 rev 2 
Page 13 
 
When in moving mode, the Zone values are Same Lane to monitor targets moving in the 
same direction as the radar and Opposite Lane to monitor targets moving in the opposite 
direction. 
This setting is not available in the Speedometer Speed Sensor models since they only 
measure patrol speed. 
 
The Units setting (20) selects the units of speed measurement.  The available options 
are MPH, km/h, knots, meters/sec or feet/sec. 
The Unit Resolution setting (21) can be set to report speeds in whole units, as 25, or 
tenths of units, as 25.4.  These settings are available on all Speed Sensor models. 
 
The Faster Target Tracking setting (13) allows acquisition and tracking of a faster 
target when a slower target has already been acquired as the strong target.  An example 
of a time when this capability is helpful is when a small car is passing a large truck.  The 
truck is reported as the main target because of its larger size.  The car is then reported 
as the fast target. 
 
The Aux Pin Configuration setting (16) sets up the AUX pin for audio, speed alarm or 
no function.  Refer to the Auxiliary Connections section in Chapter 3 and the Monitoring 
the AUX Pin section in Chapter 6 for more details on the physical connections and the 
functions of the AUX pin. 
When configured for Audio, status beeps and Doppler audio are transmitted from the 
AUX pin.  Use the settings in Section 8 of this appendix for detailed configuration of the 
audio functions. 
When configured for the Speed Alarm feature, use the Alarm Speed Threshold setting 
described in Section 7 of this appendix to set up the target speed where the speed alarm 
activates. 
This setting is only available on the Stationary and Traffic models.   
 
2.  Serial Port Configuration 
 
SETTING 
ID 
Serial Port Baud Rate 
29 
Serial Port Output Format 
30 
Leading Zero Character 
23 
Direction Character Enable 
91 
Zeros After Target Loss 
98 
Message Period 
31 
Update On Change Only 
93 
Zero Report 
92 
Format D Polled Modes 
90 
 
Use the settings in this section to configure the speed messages transmitted out the 
serial port. 
 
The Serial Port Baud Rate setting (29) configures the baud rate in the range from 300 
to 38400.  The default value for all Speed Sensor models is 9600 bits per second.  
Regardless of the baud rate, the serial port is always configured for 10 bit asynchronous 
data with 1 start bit, 8 data bits, 1 stop bit and no parity (8N1).