Vantage Pro2 Troubleshooting Guide
38
Troubleshooting Reception Problems
While we have tested the Wireless Vantage Pro2 radio extensively, each 
site and each installation presents its own issues and challenges. Obstruc-
tions, particularly metallic ones, will often cut down your station’s recep-
tion distance. Be sure to test reception between the console and ISS, in the 
locations you intend to install them, or before permanently mounting your 
ISS or other transmitter(s).
De
Dew Point reading seems 
too high or too low
Check calibration numbers for temperature. Remember, dew point 
depends on temperature and outside humidity. Make sure they’re 
working.
Te
m
pe
ra
tu
re
Outside temperature sensor 
reading seems too high
Check calibration number and adjust if necessary. ISS or temp sen-
sor may need to be relocated. See ISS or other transmitter manual.
Inside temperature sensor 
reading seems too high
Move the console out of direct sunlight. Make sure that the console 
or sensor is not in contact with an exterior wall that heats up in sun-
light or when outside temperature rises. Make sure the console or 
sensor is not near a heater or other internal heat source (lamps, ap-
pliances, etc.). Also make sure the console backlight is not on. 
Check calibration number and adjust if necessary.
Outside temperature seems 
too low
Check calibration number and adjust if necessary. Sprinklers may 
be hitting the ISS radiation shield. Relocate. See ISS manual.
Inside temperature sensor 
reading seems too low
Make sure the console or other temperature sensor is not in contact 
with an exterior wall that cools down when outside temperature 
drops. Make sure the console or other temperature sensor is not 
near an air conditioning vent. Check calibration number and adjust 
if necessary. 
W
ind Direction
Wind direction reading is 
dashed out
Wireless model - check reception. See Reception Problems 
below.
Cabled model - cable may be faulty.
If these steps do not reveal the problem, the anemometer may be 
faulty. Call technical support for return authorization.
Wind direction always says 
north
Usually an ISS problem, especially if outside temperature is dashed 
out as well. See the ISS manual for troubleshooting information
Chill
Wind chill reading seems too 
high or too low
Check calibration numbers for temperature. Remember, wind chill 
depends on temperature and wind speed. Make sure they’re work-
ing.
Heat
Heat Index reading seems 
too high or too low
Check calibration numbers for temperature. Remember, the heat in-
dex depends on temperature and outside humidity. Make sure 
they’re working.
Rai
n
No rain readings
Make sure cable-tie is removed from rain collector. See the ISS 
manual. 
Ti
m
e
Incorrect times for sunrise 
and sunset
Check your latitude, longitude, time zone, and daylight savings time 
settings. Sunrise and sunset times are calculated from the console 
using all of these settings.
T
ABLE
 4-1: T
ROUBLESHOOTING
 G
UIDE
Problem
Solution