FLIR Commercial Systems Inc. RT30 Manual De Usuario
RT30
™ Engineering Design Specification
Page 6 of 20
4.0 SYSTEM
SPECIFICATIONS
4.1 G
ENERAL
S
PECIFICATIONS
Transmitter Unit
Receiver Unit
Display
Power, Detect, External Probe LEDs
Power, Detect, Communications LEDs
3-position slide switch
Controls
Momentary switch for aux. functions
3-position slide switch
NCV: 2,000 samples/sec.
LDR: 4 samples/sec.
Sample Rate
External Probe: 2,000 samples/sec.
n/a
EU Version: 868.4MHz, 869.0MHz, 869.6MHz
Transmission Frequencies
NA Version: 913.4MHz, 914.0MHz, 914.6MHz
Transmission Distance
~100m in an unobstructed field
Transmission Power
+10dBm
n/a
Transmission Rate
4 updates/second
Immediate reception
NCV Detection (50-60Hz)
< 20mS
n/a
Light Detection
< 100mS
n/a
Alarm Status
Visual
Visual and audible
External Probe Port
Yes
No
Power Supply
Two (2) ‘AAA’ batteries
Two (2) ‘AAA’ batteries
Battery Life
3-4 weeks (4 hrs/day use), using
alkaline batteries
1-2 week (4 hrs/day use), using
alkaline batteries, Silent mode
Operating Temperature
14 to 122°F (-10 to 50°C)
Storage Temperature
-14 to 140°F (-30 to 60°C)
Operating Humidity
90%, 32-86°F (-10 to 30°C)
75%, 86-104°F (30 to 40°C)
45%, 104-122°F (40 to 50°C)
Storage Humidity
90%
Dimensions TBD
TBD
Weight TBD
TBD
Confidential and Proprietary, Extech Instruments