FLIR Commercial Systems Inc. RT30 Manuale Utente

Pagina di 20
  
RT30
™ Engineering Design Specification
 
 
Page 6 of 20
                  
4.0 SYSTEM 
SPECIFICATIONS 
4.1 G
ENERAL 
S
PECIFICATIONS
 
 
 
Transmitter Unit 
Receiver Unit 
Display  
Power, Detect, External Probe LEDs 
Power, Detect, Communications LEDs 
3-position slide switch 
Controls 
Momentary switch for aux. functions 
3-position slide switch 
NCV:  2,000 samples/sec. 
LDR:  4 samples/sec. 
Sample Rate 
External Probe:  2,000 samples/sec. 
n/a 
EU Version:  868.4MHz, 869.0MHz, 869.6MHz 
Transmission Frequencies 
NA Version:  913.4MHz, 914.0MHz, 914.6MHz 
Transmission Distance 
~100m in an unobstructed field 
Transmission Power 
+10dBm 
n/a 
Transmission Rate 
4 updates/second 
Immediate reception 
NCV Detection (50-60Hz) 
< 20mS 
n/a 
Light Detection 
< 100mS 
n/a 
Alarm Status 
Visual 
Visual and audible 
External Probe Port 
Yes 
No 
Power Supply 
Two (2) ‘AAA’ batteries 
Two (2) ‘AAA’ batteries 
Battery Life 
3-4 weeks (4 hrs/day use), using 
alkaline batteries 
1-2 week (4 hrs/day use), using 
alkaline batteries, Silent mode 
Operating Temperature 
14 to 122°F (-10 to 50°C) 
Storage Temperature 
-14 to 140°F (-30 to 60°C) 
Operating Humidity 
90%, 32-86°F (-10 to 30°C) 
75%, 86-104°F (30 to 40°C) 
45%, 104-122°F (40 to 50°C) 
Storage Humidity 
90% 
Dimensions TBD 
TBD 
Weight TBD 
TBD 
 
 
 
Confidential and Proprietary, Extech Instruments