Risco Ltd. RWT312PR4 Manual De Usuario

Descargar
Página de 64
 
 Installation 
Instructions 
 
7
 
English 
Changing Back Tamper position 
The back tamper is by default secured on the right 
side of the internal base (Rear view). If you wish to 
move it to the left side (rear view), do the following 
(Figure  5): 
1.  Remove tamper screw 1 in order to release the 
tamper from position 7. 
2.  Ensure tamper spring (2) rests over tamper wire 
base 4. 
3.  Ensure plastic tamper bracket (3) rests over 
both 2 and 4. 
4.  Secure tamper screw (1) into (3) over position 6. 
Figure 5 
 
Left
 Side 
Tamper
Right
  Side 
Tamper
3
6
1
2
4
7
5
 
Figure 5
 
Notes:  
1.    Verify that you hear a "Click" when attaching the tamper spring to the wall. 
2.    For pole installation, the tamper can be moved to the bottom right-hand side of the internal base. 
Back Tamper Terminal Wiring 
If you wish to use the back tamper (recommended) remove the short from the back tamper terminal 
block and connect the back tamper wires to the back tamper terminal block. 
 
Back Tamper in use
BACK TAMPER
Back Tamper not used
Short
H1
H1
 
DIP Switch Settings 
1 2 3 4 5 6
ON
Factory
Default
 
DIP 1: LEDs operation 
On: LEDs enabled 
Off: LEDs disabled 
DIP 2-3: PIR Detection Sensitivity  
Sensitivity 
DIP2 
DIP3 
Low Off 
Off 
Mid Off 
On 
Normal  
On 
Off 
Maximum On On 
 
DIP 4: Supervision time 
On: 65 minutes 
Off: 15 minutes 
DIP 5: Normal/Test modes 
On: Test  
Off: Normal  
DIP 6: Anti masking operation 
On: Enabled 
Off: Disabled