Installation Instructions 
Walk test 
Two minutes after applying power, walk test the protected area to verify 
proper operation. 
For installations on uneven surfaces slide the PCB inside the internal base to 
the appropriate setting according to the desired height (1.0m, 1.5m, 2.2m, 
2.7m) as printed on the bottom left corner of the PCB or use the standard 
swivel accessory. 
For reducing the detection range, slide the PCB up or tilt the swivel down.
 
1.50M
2.20M
2.70M
1.00M
PCB
 
LEDs Display 
LED 
State 
Description 
RED 
Steady Indicates 
ALARM 
 
RED & YELLOW 
RED followed By 
YELLOW 
Indicates ALARM + Anti-masking 
Operational Modes: 
Operational Mode 
Description 
Normal 
Dead time (between detection alarms) is 2.5 Minutes. 
Test (walk test) 
Dead time (between detection alarms) is 2.5 sec. 
Write 
The unit transmits a WRITE message each time both of the Tamper 
Switches (back and cover) are closed for at least 3 seconds. 
Notes:  
After power up the detector enters into test mode for a period of 20 minutes (disregarding the DIP switch Modes 
Position). 
Transmitter/Receiver Communication link setup 
The detector must identify itself to the system’s receiver by writing its coded message into the 
receiver’s address memory. This is accomplished by performing the following steps: 
1. Set the receiver to Write Mode. 
2. Remove the insulation material from the batteries and place them in the batteris holders on 
the PCB on the right direction (pay attention to the "+" and "–" diagram on the PCB) 
3. Send a WRITE message by pressing both of the tamper switches (back and cover) for at 
least 3 seconds.  
4. Verify that the detector has been identified by the receiver. 
CAUTION NOTICE 
Changes or modifications not expressly approved by RISCO Group may void the user’s authority to 
operate this equipment. 
Simultaneous transmissions from two different units may cause message interference resulting in 
loss of information. 
The communication quality of this unit may be affected by its surrounding environment. Nearby 
electrical equipment may interfere with its normal operation. 
The operation of this unit must, therefore, be tested at each installation since its transmission 
quality may vary as a result of operational conditions. 
NOTE: 
DIP-Switch 1 should be in ON position to enable LED indications (regardless during the first 20 minutes after 
power up).