packet sent and for all subsequent retries.
Some data has possibly been lost. LF is
not functional if all active ports are set to
NAR mode.
Link fails are inevitable during normal
operation (mobiles temporarily out of
range, in a tunnel, parked in a dead spot,
etc.). A lit LF LED is not normally cause
for concern.
UF
Unit Failure - when lit, the unit requires
attention:
 - The BDLC
PD
 is not operable;
It may indicate detection of a system
software error trap.
- The BDLC
PD
 is operable;
Indicates that on power-up, invalid data
was detected in the serial EEPROM chip
(located in the radio modules). It may
also indicate that connection to the radio
modules is incorrect or that radio power
is not applied.
The LMRM and UF alarms also sound a beep
when a fault occurs. The LF alarm is silent.
3.2.2 BDLC
PD
 Rear panel
PD
 has the following set of chassis con-
nectors:
 
One DB-25F connector
–  DEV1 - Connects to user’s application.
a)  DMP 19200 or 38400 baud for single-
site installations
b)  MSCP 19200 or 38400 baud for multi-
site installations
  Four DE-9F connectors:
–  DEV2 - usually connected to Dataradio’s
WinRIS program  (Dedicated or DMP at
19200 baud).
–  DEV3 - Dedicated (up-to 9600 baud)
–  DEV4 and DEV5 - not used
 
One DA-15M connector:
–  DEV6 Digital I/O - not used
 
One DB-25M connector:
–  EXT RADIO/TEST - connects to the Ra-
dio assembly through the radio interface
cable (see Figure 15)
3.2.2.1 RS-232 Signal Levels
In the description of data signals in Table 7, the
following conventions are used:
Table 5 - RS-232 Signal levels
Term
Alternates
Signal level
ON
Asserted, spacing
+3 to +15 V
OFF
Dropped, marking
-3 to -15 V
3.2.2.2 Pin Functions
Table 6 - DTE Port 9-pin funtions
DE-9 F
pin #
Function (RS-232 signal levels)
1
DCD – from Paragon
PD
, normally asserted
2
RXD – data from Paragon
PD
3
TXD – data to Paragon
PD
4
DTR – to Paragon
PD
, handshaking
5
Ground
6
DSR – from Paragon
PD
, tied to VCC through
current limiting resistor
7
RTS - to Paragon
PD
, handshaking
8
CTS – from Paragon
PD
, handshaking
9
Reserved
Table 7 - DTE Port 25-pin functions
DB-25F
pin #
Function (RS-232 signal levels)
1 and 7
Ground
2
TXD – data to BDLC
PD
3
RXD – data from BDLC
PD
4
RTS – to BDLC
PD
, must be asserted
5
CTS – from BDLC
PD
, handshaking
6
DSR – from BDLC
PD
, always +8V
8
DCD – from BDLC
PD
, always asserted
9
RI      - from BDLC
PD
, always –8V
20
DTR – to BDLC
PD
, handshaking
We recommend the use of shielded 9-wire or
25-wire cables with all pins connected.
Dataradio recommends the use of secure (i.e.
password protected and/or dial-back) modems in
any installation where dialup access is provided.
.