120 20170-200
Paragon
PD
 Technical Manual
20
Figure 17 - “Connect using” dialog window
4.4.1.1 Connect 
Button
The Connect button is used to establish the re-
quired communication link with the connected
Paragon
PD
 unit.
1.  Press the Connect button to open the  “Con-
nect using ” dialog window (see  above).
2.  Select the appropriate COM port where the
Paragon
PD
’s RS-232 cable is connected on
your PC or portable computer and the port
speed (usually 19200) for the COM port
selected. This speed is independent of the
network bit rate. Bit rates from 2400 to
19200 are supported.
3.  Click OK. This validates the options entered
and starts the connection sequence.
The program briefly displays pop-up window
messages as it establishes a communications link
with the equipment. Their content is not normally
user-sensitive and only denotes proper operation.
If an Error window opens, check the connections
and that the right options were selected in the
“Connect using” dialog window.
Selecting an incorrect port speed in the “Connect
using” window will result in the status bar re-
porting Connection failed!
When communication linking is complete:
  The Status bar reports Connection estab-
lished.
  All of the buttons grayed-out at startup be-
come available.
  The “Comment” and “Password” fields and
their respective Put buttons are activated.
  The product field indicates the product
model connected to.
  The Banner information is displayed.
4.4.1.2 “Get” 
button
After communication is established using the
Connect button, press the Get button to down-
load and automatically save the connected
BDLC
PD
 configuration setting to a file named
with the unit's on-air address (as set at the time
of manufacture). The RIS status bar will then
report  “All parameters are successfully re-
trieved  and saved in file [unit's on-air ad-
dress].bp2.
 Any previous configuration in the
program is overwritten.
If you do not wish to overwrite an existing con-
figuration or prefer to name the file yourself, use
the Get As button.
Example: In a network using multiple BDLC
PD
having a common address, using the “Get As”
button allows to uniquely name the files.
4.4.1.3 
“Get As” button
After communication is established using the
Connect button, press the Get As button to:
  Open the “File, Save As” window with the
ASCII file *.bp2 (already selected).
  Save the connected BDLC
PD
’s operating
characteristics (configuration setting) to a
file, directory or drive of your choice.
The program will ask before overwriting an
existing file.
  Status bar reports “All parameters are suc-
cessfully retrieved and saved in [filename].
Connect using
COM1
9600
OK
Cancel