Table 6 - Checklist B (General) 
CHECKLIST B (Paragon-3) General Check out  
Paragon3 units are set and characterized at the factory to optimize performances.  
It is not recommended to try readjusting units unless it is really required.  
Misadjusting a unit may result in significant performance losses. 
The proposed adjustments in the "IF NOT?" column below, should be tried ONLY if system data perform-
ance degradation is noticed combined with out-of-tolerance items. 
Step 
ACTION 
Expected Results at 25
°
MEASURE WITH 
IF NOT? 
Normal Power-up  
Sequence  
 
BSC 
 
PWR LED lights red for four second, turns amber for one second, and stays green 
thereafter.  
TX LED flashes green once about fifteen seconds after power-up then keeps flash-
ing in-tune to the cycle marker 
RX LED remains OFF 
STATUS LED remains OFF      
ETH 1 LED – if connection present – lights green. Flashes amber with activity 
ETH 2 LED – If connection present – lights green. Flashes amber with activity 
Receivers 
GATE LED  must remain steady red  
SUPPLY LED must remain steady green 
Transmitter 
SUPPLY LED must remain steady green  
ON LED  lights red for one second, turns OFF for 10 seconds,  and stays red 
thereafter 
For steps below, on the Radio Î Set Up Web page, press the “test” button to enable Test Tone function 
Transmitter Output Power 
 
From the Maintenance unit WEB 
“Test Tone” page, select  
 
Unmodulated – Press Execute 
Adjustment range: 
35 - 70 watts
 
Tolerance: +15%  -20% 
Service monitor set to 
read power 
or 
100W in-line wattmeter 
installed as close as pos-
sible to the unit antenna 
connector. 
Adjust “Power” on the 
power amplifier front 
panel  
(Figure 4, page 6) 
Transmitter Reflected Power 
From the Maintenance unit WEB 
“Test Tone” page, select  
Unmodulated – Press Execute
 
< 5% of forward power or 
as specified by System 
Engineering.  
10 W in-line wattmeter 
Check for bad connec-
tions, damaged coax 
cable, etc. 
Carrier Frequency Error 
From the Maintenance unit WEB 
“Test Tone” page, select  
 
Unmodulated – Press Execute 
< ±300 Hz 
Service monitor set to 
read frequency error 
Adjust TCXO (IC700) 
(see inside Exciter 
module at, Figure 51 
TX Deviation (kHz) 
From the Maintenance unit WEB 
“Test Tone” page, select  
 Modulated – Press Execute 
Carrier will be modulated with a      
1 kHz tone. 
Refer to Table 7 for TX 
Deviation details 
 
Tolerance is +5%, -10%
 
Service monitor set to 
read deviation. 
(IF filter set to Mid or 30 
kHz position) 
 
Low Frequency Balance 
From the Maintenance unit WEB 
“Test Tone” page, select  
Random data – Press Execute
 
a)  Record deviation level 
read from step 5 
b)  Record deviation read 
from TX Random test 
c)  Difference between  a) 
and b) should be:    
< 2.5 kHz (SRRC16FSK) 
Service monitor set to read 
deviation 
 (IF filter set to Mid or 30 
kHz position, all audio 
filtering disabled )