CALAMP WIRELESS NETWORKS INC. BDP3-CRE700 Manual De Usuario

Descargar
Página de 72
 
 
120 20194-102 
 
Paragon3 – 700/800MHz User Manual
 
50
12dB SINAD 
(Dataradio wide band measurement 
method: no audio filtering)
 
Set deviation to  ±6 kHz in 700MHz 
or ±3 kHz in 800MHz units. 
 
Better than  -105 dBm  
including cable loss 
(Typically -106 dBm) 
 
Backplane test points as 
detailed in Table 4 and 
Figure 15 
 
Receiver distortion 
(Dataradio wide band measurement 
method: no audio filtering)  
 
Set service monitor RF Gen output 
to –70 dBm 
 
Deviation level as per SINAD above.
 
≤ 3.0 % 
(Typically < 2.5 %) 
Backplane test points as 
detailed in Table 4 and 
Figure 15 
 
RSSI 
Apply to each receiver input a RF 
level of -110dBm
 
1.4 VDC (+/- 0.2VDC) 
 
BSC must be connected to 
the radio during the meas-
urements 
Backplane test points as 
detailed in Table 4 and 
Figure 15 
 
 
5.3  Additional test details 
5.3.1 Carrier Deviations 
Table 7 – Carrier Deviations 
Carrier Modulation 
SRRC4FSK 
SRRC8FSK 
SRRC16FSK 
 
 
 
Tone 
 
Tone 
Network Speed 
(kb/s)
 
Typical deviation 
in kHz 
(1000Hz test tone) 
Network Speed 
(kb/s)
 
Typical deviation 
in kHz 
(1000Hz test tone) 
Network Speed 
(kb/s)
 
Typical deviation 
in kHz 
(1000Hz test tone) 
Wide Channel (700MHz) 50kHz bandwidth 
64.0 
± 4.6 
96.0 
± 5.8 
128.0 
± 5.8 
Full Channel (800MHz) 25kHz bandwidth 
32.0 
± 2.4 
48.0 
± 2.7 
64.0 
± 2.9