13
3.1.5  Power Supply Modules (T809)
Figure 9 - Dual T809 Power Supply Module (black front plate)
Two horizontally mounted switched-mode pulse-width modulated T809 power supply modules are used
but not connected in parallel.
Both power supply units have an ON-OFF switch* and one LED indicator on the front panel plus an out-
put voltage adjust potentiometer (13.8 VDC nominal, 13.5 to 18 VDC) accessed via the back panel.
To remove voltage from the power supply PCB, disconnect the main power cords.
Their circuit protection features are:
•  Inrush current limiting
•  Over-current (short-circuit)
-  37 to 48A constant current limiting
-  Reset = auto recovery
•  Over-voltage 
-  18 to 21 VDC = shutdown
-  Reset = Power OFF and ON
•  Over-temperature
-  shutdown of output voltage
-  auto recovery with temperature reduction
-  temperature sensed on transistors and diodes
Front Panel Indications
Power Switch
Illuminates when the unit is connected to AC power and
voltage is available
ON LED 
- Lights bright green when voltage output is normal
- Lights faint green when module has entered over-
current mode
- Green LED is OFF, but power switch is ON indicates
module has shut down due to over-temperature or over-
voltage conditions.
Dual Power Supply Module
Power
Power
ON
ON