Crestron Electronics Inc CEN-RFGW-EX Manual De Usuario

Descargar
Página de 36
InfiNET EX™ Gateway 
Crestron CEN-RFGW-EX 
Operation 
Operating 
Channel 
The operating channel of the CEN-RFGW-EX must be set prior to 
operation using Crestron Toolbox. The CEN-RFGW-EX can operate on 
one of 16 channels. The CEN-RFGW-EX can operate on a fixed channel 
that is set by the installer. The default RF channel is 15. 
For optimum performance when installing a CEN-RFGW-EX in a Wi-Fi 
environment, do not set the CEN-RFGW-EX to a channel within a Wi-Fi 
channel band. Crestron recommends channel 15 or channel 20. 
•  Gateway channels 11-14 are within Wi-Fi channel 1 band. 
•  Gateway channel 15 is adjacent to Wi-Fi channels 1 and 6. 
•  Gateway channels 16-19 are within Wi-Fi channel 6 band. 
•  Gateway channel 20 is adjacent to Wi-Fi channels 6 and 11. 
•  Gateway channels 21-24 are within Wi-Fi channel 11 band. 
•  Gateway channel 25 is adjacent to Wi-Fi channel 11. 
•  Gateway channel 26 is neither within or adjacent to any Wi-Fi 
band. 
For detailed information on RF channels, refer to “Appendix A:  The RF 
Spectrum” on page 24. 
After establishing communication with the CEN-RFGW-EX (refer to 
“Establishing Communication” which starts on page 15), use Crestron 
Toolbox to set the operating channel. 
 
RF Channel 
Each gateway can communicate with up to 16 infiNET EX devices on the 
same channel. Each device must have an RF channel assignment that 
matches the RF channel assignment of the gateway. 
There are 16 possible channels ranging from 11 to 26. 
Setting RF channel is done from a PC via Crestron Toolbox. To access 
this in Toolbox, select Functions | infiNET EX Gateway…. Refer to the 
Toolbox Help file and search for “infiNET EX Gateway” for more 
details. 
 
 
18  
  infiNET EX™ Gateway: CEN-RFGW-EX  Operations & Installation Guide – DOC. 6706B