Bird Technologies Group 61170A Manual De Usuario

Descargar
Página de 28
TX RX Systems Inc.                             Manual 7-9469-1.7                              02/08/10                                Page 10
Message
Context
Ready to connect
The Applet has finished loading and has not attempted to connect to the 
control board.
Network connection established
Upon successful connection to the control board.
Not connected
The Applet either is not connected or has failed to connect to the control 
board.
No network connection
Unable to reconnect to the control board.
Table 3: Connection status messages.
Message
Context
Obtained startup data successfully
Connection to control board has been established and data and settings for 
the active module uplink/downlink have been successfully obtained.
Failed to connect to booster
Initial attempt to connect to the control board failed.
Network client restarting
Reconnecting to the control board.
Network connection restarted
Reconnected to the control board successfully.
The page was reloaded
Successful reload of settings or data for a page (Admin, System, CPS)
Submitting network settings
User clicked the “Submit” button to send the network settings to the control 
board.
Failed to submit network settings
An error occurred while sending network settings to the control board.
Network settings updated successfully
The network settings have been sent and applied successfully.
Password settings updated successfully
The password settings have been sent and applied successfully.
Failed to update password settings
An error occurred while sending password settings to the control board.
Requesting device readings
Requesting data from the control board for the active module (temperature, 
current measurements, etc...)
Obtained device readings
Obtained data successfully
Submitting system settings
User clicked the “Submit” button to send the system settings to the control 
board.
System settings submitted
The system settings have been sent and applied successfully.
Failed to submit system settings
An error occurred while sending system settings to the control board.
Data Sequencer : Error submitting query
General communication message error.
Sending the factory reset command
User clicked the “Factory Reset” button.
The factory reset command was sent
The control board has restored factory default settings.
Sending the device ID command
User clicked the “Send ID” button.
The device ID command was sent
The control board has executed the “Send ID” command.
Sending the device clear errors command
User clicked the “Clear Errors” button.
Table 4 (part 1): System status messages.