Digital Security Controls Ltd. 02RF5501433 Manual De Usuario

Descargar
Página de 32
10
Program the (P)WLS909-433 or (P)WLS919-433 Function
Buttons
(P)WLS909-433 and (P)WLS919-433 wireless keys have four programmable function
buttons.  Default functions have been assigned, but you may program other functions
if desired.  After the functions are programmed, when you press and hold one of the
four buttons for one second, the system will execute the programmed function.
For systems using partitions (PC5020/P-8+/PC501X/P832/P832DL only): All wireless
keys assigned to Partition 1 will have the four functions programmed in section [61]. All
wireless keys assigned to Partition 2-8 will have the four functions programmed in section
[62-68]. For example, if function button 1 in Section [61] is programmed for Stay arming, then
pressing the first button on wireless keys assigned to Partition 1 will Stay arm Partition 1.
NOTE: Wireless keys will not work when the partition they are assigned to is being
accessed for zone bypassing or programming.
1. At a system keypad, enter [
✱][8][Installer’s Code].
2. Enter programming section [804].
3. Enter programming section [61] to [68] for partitions 1 to 8.
4. For each of the 4 function buttons, enter the 2-digit number of the function you want
to select. See the programming worksheets in the back of this manual for a list of
function key options.
5. Record your programming choices in the worksheets in the back of the manual.
6. To exit press [#].
3.5 Identified Wireless Keys
Reporting by the system of openings/closings by individual wireless keys and
command output [
✱][7] activation by wireless key buttons may be supported on
certain control panels. To do this, the system will reserve access codes 17 – 24 for
wireless keys 01-08 respectively. You must program one access code for each
wireless key (using [
✱][5] access code programming) for this feature to work correctly.
NOTE: Program these access codes on the system after you have connected the
PC5102-433  to the Keybus (see section 2.4).
Refer to your system 
Installation Manual for information on access code programming.
Opening/Closing By Wireless Key Reporting
NOTE: The Identified Wireless Key Closing option is only available with the PC5020,
P-8+,  PC501X v2.0 and higher, P832/DL v2.0 and higher, PC1555(MX), P-6B(MX),
PC580 v2.0 and higher, P-48 v2.0 and higher by turning section [015] option 4 off.
To enable the reporting of openings and closings
 by identified wireless keys:
• Make sure the control panel is v2.0 or higher
• Program a valid access code for each key
• Program a closing and opening reporting code for each key’s access code
• Turn off the Quick Arm option in section [015] option [4] of the control panel
programming
E  N  R  O  L  L    &    P  R  O  G  R  A  M    D  E  V  I  C  E  S