E  N  R  O  L  L    &    P  R  O  G  R  A  M    D  E  V  I  C  E  S
To ensure that an 
unidentified wireless key cannot disarm the system, turn off section
[017], option [1] (in the control panel programming). This option is available in control
panels with software version 2.1 or higher.
3.6 PC5102 PGM Outputs
The PC5102-433 has two on-board Form C relay PGM outputs.  Each of these can be
individually programmed to:
1. Follow main panel PGM outputs 1 to 14.
NOTE: Please refer to your System Installation Manual for available PGM outputs.
NOTE: If the PC5102-433 is connected to the PC580/PC1555/P-48/P-6B (all versions),
PC5010 v1.x, P832 v1.x or the WSS5010 1.0, 2.1, the PC5102 PGM outputs cannot be
programmed to follow main panel PGM outputs 1 or 2.
2. Activate for a programmable amount of time when a signal is received from a wireless
key programmed with output option 31 or 32 (PC5102 PGM pulse) and the PGM
output programming section [92] or [93] is programmed with option 15 (PC5102
PGM pulse).  The amount of time that the PGM outputs can be programmed to
remain on is programmed in sections [94] and/or [95]. The default activation time is
5 seconds.
3.  Toggle state when a signal is received from a wireless key programmed with option
31 or 32 and the PGM output programming section [92] or [93] is programmed with
option 16 (PC5102 PGM toggle).
3.7 Deleting Wireless Devices
To remove a wireless device from the system, follow the guideline for adding a wireless
device. Program the ESN as [000000]. The wireless device for the zone will be removed.
NOTE: You may need to remove power from the panel in order to clear troubles caused
by deleted zones.
Now that you have enrolled all the wireless devices, you will need to program the system
to work properly with the devices. See section 4 for more information.