Digital Security Controls Ltd. 15TL2553GRE Manual De Usuario

Descargar
Página de 38
[996] Cellular Telephone Number
NOTE: This Section will display the Cellular telephone number of the SIM. This telephone number is required by the Installer
for DLS and remote firmware (flash) update. User can access this telephone number by entering [*] [6] < > “Cellular
Phone No.” to display the phone number.
[997] IMEI Number
This Section will display the unique 15- digit International Mobile Equipment Identity (IMEI) of the radio. Format is: Reporting
Body Identifier (2 digits), Allocation Number (4 digits); Final Assembly Code (2 digits); Serial Number (6 digits); and a check
digit.
[998] MAC Address
This Section will display the unique12-digit, hexadecimal number assigned as the Media Access Control (MAC) address of the
device.
System Reset Defaults
[999] Software Default
Default (99);
The Software default allows the installer to refresh the unit after changes and also return the Communicator to the default state.
00: Default Module. All programming Sections in module revert to factory settings. This will erase all existing programming of
the unit.
55: Reset. The Communicator is reset. This option is equivalent to power cycling the Communicator.
Communicator Troubleshooting
[984] Communicator Status
The communicator status sections are intended to provide the installer with real-time status of the communicator’s functionality,
operational readiness, failures, and potential malfunctions that may affect flawless operation of the communicator and its
primary function of sending signal to the central station in case the monitored event occurs.
The communicator status is displayed in the form of a 6- digit CODE (6 hexadecimal numbers) as in the following pattern:
00000F. The range of the code is from: 00000F – 2220CF. Not all numbers in this range are assigned a status code (Some
numbers are skipped, i.e. not assigned the code).
Each digit represents a status or trouble indicator (or assigned function when no trouble is present) as described below:
1. Digit 1 - Signal Indicator 1, displays the presence/strength of signal 1.
2. Digit 2 - Signal Indicator 2, displays the presence/strength of signal 2.
3. Digit 3 - Network Indicator, displays the presence (operational status) of network.
4. Digit 4 & 5 – TROUBLE INDICATOR displays the type of problem/malfunction on communicator or modules associated
with and connected to communicator.
5. Digit 6 – Reserved for future use.
For example, status code 11002F – when interpreted means: “Signal Indicator 1 OK, Signal indicator 2 OK, there is no network
trouble, and there is trouble in the communicator, Panel supervision trouble.” For details see the table below:
Table 15: Communicator Status and Trouble Coding in Hexadecimal Numbers
Digit 1
Digit 2
Digit 3
Digits 4 & 5
Digit 6
Signal Indicator 1 Signal Indicator 2 Network Indicator
TROUBLE INDICATOR
Future Use
0
Off
0
Off
0
Off
00
Off (No trouble)
F
1
On
1
On
1
On
01
Future use
F
2
Flashing
2
Flashing
2
Flashing
02
Panel supervision trouble
F
03
Future use
F
04
Lockout trouble
F
05
3G/Cellular trouble
F
06
Ethernet Trouble
F
07
Receiver Not Available
F
08
Receiver Supervision trouble
F
09
FTC Trouble
F
0A
C24 Configuration SMS Failure
F
0B
Future use
F
0C
Module configuration Trouble
F
26