FlexWave Prism Remote Unit RF Module Installation Guide
©2015 TE Connectivity
TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015
Close the Remote Unit Door and Solar Shield
1
Do not slam the door to close it—gently swing the door shut and press it firmly closed. 
2
Slowly close each door latch in a smooth fluid motion—do not allow the door latches to snap closed. For best 
results, starting with the top latch and working down to the bottom latch, use a flat-head screwdriver to close 
each latch as shown below.
3
Do not slam the Solar Shield to close it—gently swing it shut and press it firmly closed. 
Solar Shield
Door
Door latch
CAUTION! Service personnel must confirm that the perimeter gasket and door-to-door gaskets are in place when 
closing the Remote Unit doors after servicing.
CAUTION! If the PRU door was allowed to snap closed, RF output from an HDM RF Module may be disabled for up 
to three minutes. Any alarms generated immediately following the opening/closing of the PRU Doors, 
such as Door Open, RF Power Low, System VSWR Fault, and LPA VSWR Fault, automatically clear once 
the RF has recovered. If alarms do not clear after three minutes, please contact TE for technical support; 
see 
Provision the Prism Remote Unit 
Refer to the current EMS System Setup and Provisioning Guide for information on configuring the PRU for a 
FlexWave Prism system.