Installing the Encompass 4/4800 Multiprotocol Reader
4-27
3.
Connect either the yellow or black wire (signal ground) from the yellow and 
black wire pair to pin 5 of the DB9 connector or pin 7 of the DB25 connector. 
4.
Plug the DB9 connector or DB25 connector into the PC. 
If the host is set up for hardware handshaking, use the following procedures:
1.
Connect the yellow wire (RTS) from the yellow and red wire pair to pin 8 of the 
DB9 connector or pin 5 of the DB25 connector. 
2.
Connect the red wire (CTS) from the yellow and red wire pair to pin 7 of the DB9 
connector or pin 4 of the DB25 connector.
RS
422 Interface
RS
422 interface signals are supplied by four wires from the Encompass 4/4800 Mul-
tiprotocol Reader communications cable. Your host must have an RS
422 interface 
with either an internal or external converter. 
422 signals and their interface wires.
To connect the colored-wire cable using RS
422 interface
1.
Connect the yellow wire (transmit +) from the yellow and red wire pair to the 
host receive (+) signal.
2.
Connect the red wire (transmit 
) from the yellow and red wire pair to the host 
receive (
) signal. 
3.
Connect the black wire (receive +) from the red and black wire pair to the host 
transmit (+) signal.
4.
Connect the red wire (receive 
) from the red and black wire pair to the host 
transmit (
) signal.
Table 4-8  RS
422 Interface Signal Wiring for Colored-Wire Pair Cable
Signal from Encompass 4/
4800 Multiprotocol Reader
Colored-Wire Pair Cable
Connect to 
Signal from 
Host
Wire Pair 
from 
Encompass 
4/4800 
Multiprotocol 
Reader
Color Used
RS
422 Transmit positive
Yellow/Red
Yellow
Receive (+)
RS
422 Transmit negative
Red
Receive (–)
RS
422 Receive positive
Red/Black
Black
Transmit (+)
RS
422 Receive negative
Red
Transmit (–)
Signal Ground
Yellow/Black
Yellow or 
Black
Signal Ground