Choosing A Mounting Location 
 
The Door/Window Detector is suitable for mounting in dry interior locations only. 
 
Decide which doors/windows are to be protected by Door/Window Detectors, 
(usually the front and back doors as a minimum will have Door/Window Detectors 
fitted).    Additional detectors may also be fitted where required to other vulnerable 
doors or windows, (e.g. garage, patio/conservatory doors etc). 
 
Note: Take care when fixing the Detector to a metal frame, or mounting within 1m of 
metalwork (i.e. radiators, water pipes, etc) as this could affect the radio range of the 
device.    If required, it may be necessary to space the magnet and detector away 
from the metal surface using a plastic or wooden spacer to achieve the necessary 
radio range. 
 
Installation 
 
1.  Ensure that the system properly powered. 
Factory default built in two CR2450 batteries inside the detector and uses a 
Mylar film to isolate batteries from electric circuit of the detector. Remove the 
battery Mylar film when ready to let the detector work. 
If there is no battery inside the detector or need to replace a new battery, please 
insert the battery in 45° angle, and then firmly push the battery into the 
compartment until the battery clicks into place, as indicated below: 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
   
 
 
2.  Using the adhesive tape to fit detector on the door or window. 
 
3.  Fit the magnet to the moving part of the door/window opposite the detector 
using the adhesive tape. 
 
4.  Ensure that the parallel gap between the magnet and detector is less than 
20mm and that the matching line on the magnet is pointing towards and aligned 
with the line on the detector. An alarm condition will be occurred if the gap is 
greater than 35mm. 
   
5.  Remove the battery cover with the tamper switch not being pressed on the 
detector (test mode), detach or close the magnet from the Detector, the LED on 
the detector will illuminate. 
 
6.  After proper installation and test, put the battery cover back to the detector and 
the detector enters the normal mode. 
 
Note: After removing batteries, wait for 5 seconds to refit batteries. 
 
Operation 
 
1.  If first use of HSM02 with no node ID, LED will start twinkling for 30 sec. to lead 
the user for Inclusion.  After HSM02 finishing Inclusion and enter sleeping 
mode, the unit will wake up by pressing Tamper and the user can see the LED 
start lighting up shortly every sec., currently the unit can receive set up for 
controller.    After 30 sec., the unit will enter sleeping mode again, if set up is 
still needed, the user can press Tamper once more for HSM02 to be awake for 
another 30 sec.   
 
2.  Due to limited power from CR2450, the unit may not continuously operate for a 
long time due to power consumption.  Therefore, set up time for HSM02 
should be minimized, and repeatedly press of Tamper should be avoided as 
well, in order to prevent unusual incident by a quick battery voltage drop down.   
 
3.  User can enter test mode by releasing or not pressing the Tamper SW, in the 
meantime if magnetic sensor is triggered then the LED will be illuminated.  
User can confirm whether the Tamper SW has been pressed properly by 
implementing this function.  When Tamper SW is to be pressed and enter 
normal mode, LED will not be illuminated even if the magnetic sensor is 
triggered, unless low battery is detected. 
Battery Cover 
45°
Battery Cover 
CR2450 
Battery