Everspring Industry Co Ltd HSM02 Manual De Usuario
3
4. When the tamper switch is pressed, the unit enters normal mode and the red
indicator LED on the Detector will not illuminate to conserve battery life when
the detector is triggered, (unless the battery power is low).
the detector is triggered, (unless the battery power is low).
Programming
1. Z-Wave’s Group (Association Command Class Version 1)
The unit supports two association groups. This has the effect that when the unit is
triggered, all devices associated with the unit will receive the relevant reports.
Grouping 1 Support ALARM_REPORT, SENSOR_BINARY_REPORT
Grouping 2 Support BASIC_SET
Grouping 1 Application (Max. node=1)
Power Applied
triggered, all devices associated with the unit will receive the relevant reports.
Grouping 1 Support ALARM_REPORT, SENSOR_BINARY_REPORT
Grouping 2 Support BASIC_SET
Grouping 1 Application (Max. node=1)
Power Applied
Once the power has been applied, Alarm Report Command will be sent to
Nodes in Grouping 1 to confirm the power applied status for HSM02.
1-1 Magnet status report: Binary Sensor Report
When the magnets of HSM02 are to be opened, Binary Sensor Report
Command (Value = 0xFF) will be sent to Nodes in Grouping 1, and when the
magnets are to be closed, Binary Sensor Report Command (Value = 0x00) will
be sent as well.
1-2 Low Battery Report
When HSM02 automatically wakes up, it will check the battery usage. When
low battery is detected, Alarm Report Command will be sent to Nodes in
Grouping 1, afterward, LED will light up for 1 sec to remind user when HSM02 is
triggered due to open or close incidents.
1-3 Tamper Event Report (Alarm Report)
Press and hold the tamper switch more than 10 seconds then release, the unit
will send ALARM REPORT command to the nodes of Grouping 1 to inform
them there is a tamper event.
will send ALARM REPORT command to the nodes of Grouping 1 to inform
them there is a tamper event.
1-4 Control other Z-Wave Devices
When door/window is opened, the unit will send BASIC SET command which
contains a value that is adjustable, to the nodes of Grouping 2. For instance,
the brightness level of a lamp module can be fixed according to the set value.
contains a value that is adjustable, to the nodes of Grouping 2. For instance,
the brightness level of a lamp module can be fixed according to the set value.
Power Applied Notice:
[Command Class Alarm, Alarm Report, Alarm Level = 0x02, Alarm Type =
0x01]
Magnets to be opened:
[Command Class Sensor Binary, Sensor Binary Report, Value =
0xFF(255)]
Magnets to be closed:
[Command Class Sensor Binary, Sensor Binary Report, Value = 0x00(0)]
Low Battery Report :
[Command Class Alarm, Alarm Report, Alarm Type = 0x01, Alarm Level =
0x01]
[Command Class Alarm, Alarm Report, Alarm Type = 0x01, Alarm Level =
0x01]
Tamper Event Report :
[Command Class Alarm, Alarm Report, Alarm Type = 0x03, Alarm Level =
0x01]
[Command Class Alarm, Alarm Report, Alarm Type = 0x03, Alarm Level =
0x01]