Cherry F-89XX Manual De Usuario

Descargar
Página de 8
4
5.1 Connecting the charging cable to the 
PC
Charging cable
Use only the accompanying charging cable.
1 Switch off the PC.
If the PS/2 port of the PC is occupied by the 
receiver: Insert the PS/2 plug of the receiver into 
the PS/2 port of the charging cable. The data is 
then transferred via the charging cable.
2 Insert the charging cable PS/2 plug into a PS/2 
port on the PC.
3 Switch on the PC.
5.2 Charging the mouse batteries
Insert the hollow connector of the charging cable 
into the socket on the front of the mouse. It does 
not matter whether the PC is switched on or off.
The mouse is charged as long as the PC is 
switched on. You can continue working while 
charging is taking place.
Tips for charging the alkaline batteries
• Charge the alkaline batteries in the mouse as 
soon as the 
 LED on the receiver flashes red. 
A total discharge can damage the inner 
structure and chemical components of the 
alkaline batteries.
• A complete charge of the alkaline batteries lasts 
12 to 18 hours. The charging circuit prevents 
overcharging. As the rechargeable alkaline 
batteries do not exhibit the so-called memory 
effect, the charging procedure can be 
interrupted several times.
• The PC must be switched on to charge the 
alkaline batteries.
• The charging cable can remain connected to 
the PC even if the mouse is not being charged.
6 Using the power-save function of 
the mouse
The power-save function switches the mouse to 
power-save mode after 15 minutes of non-use.
• In sleep mode, the surface on which the mouse 
is used is scanned only once per second. 
Moving the mouse or pressing a button exits 
sleep mode. Sleep mode is preset.
• The mouse switches off in deep-sleep mode. 
The battery life is notably lengthened by this. 
Pressing a mouse button switches it back on. 
Deep-sleep mode must be activated manually.
6.1 Activating deep-sleep mode
1 Remove the batteries from the mouse.
2 Keep the left and right mouse buttons pressed 
simultaneously and reinsert the batteries.
The setting is confirmed by 10 flashes of the 
optical sensor of the mouse.
Automatic deactivation of deep-sleep mode
When you remove the batteries from the mouse, 
deep-sleep mode is deactivated and the mouse 
returns to sleep mode. For this reason, the deep-
sleep mode must be reactivated each time after 
the batteries are removed.
7 Setting channels
The channels of the keyboard and the mouse are 
selected at random from 4,095 channels. The 
channels of the keyboard and mouse must be 
selected together.
Channel setting is necessary in the following 
cases:
• battery change
• malfunctions during operation of several 
devices in the 27 MHz frequency range