12-10
Installation & Operation Manual
Figure 33: Current Reading Example
Current Reading
Account Number - This field indicates the account number sent by Reading Data Management Software..
Service Type - This field contains the description of the service being measured by the meter, such as Water, Electric, 
Gas, etc.
Module S/N - The serial number of the ORION endpoint mounted on the meter. The serial number allows ORS 
to identify each meter uniquely.  The serial number is sent from Reading Data Management Software and is not 
editable.
Current Reading- The current reading value is stored in this field. If the meter is a gas meter, the index value and not 
the sub count appears. If the meter is unread, UNREAD appears in the reading field.
Low Reading -If the current reading is lower than this value, it will be considered low.
High Reading - If the current reading is higher than this value, it will be considered high.
Potential Leak – If the ORION endpoint detects a potential leak, LEAK is displayed below the reading.
 
The subsequent four fields are selected in the Reading Data Management Software, and downloaded to the ORS. 
Note: Refer to the Reading Data Management Software manual for more information. In this example, the five 
fields downloaded from Reading Data Management Software were (continued on next page):