Installation Data
UNRELEASED DRAFT COPY ONLY
Network Endpoint Installation
When installing an SE or ME (used with a network gateway transceiver) or CE (used with an ORION 4.0 or 2.0 gateway 
receiver) endpoint in a pit, the endpoint must be mounted through the lid of a non-metal pit lid for maximum propagation 
of the radio signal. If the endpoint is being installed indoors, a wired radio endpoint should be mounted on the outside 
of the building or in the floor joist near the outside wall of the building, and away from large metal objects for maximum 
propagation of the radio signal. 
Splicing Considerations
For non-submerged indoor and outdoor applications where splicing is necessary, splice connections together and wrap any 
cables inside the base of the housing. 
Splice connections made in pit environments require a pit field splice kit (62084-001), which can be ordered separately. 
Please refer to RTR-I-15 for field splice kit installation instructions.
ORION endpoints shipped factory pre-wired to a Badger Meter encoder require no splicing. Only the mounting of the 
encoder to the meter and tightening the TORX® seal screw is necessary.  
For all installations, excess wire should be coiled and cable tied to avoid any damage.
ORION Installation Kit Part Numbers*
TYPE
DESCRIPTION
ORION SE
ORION ME
ORION CE
PIT
Through the Lid Installation Kit
64394-024
64394-024
64394-001
Below Lid with Knuckles  
Installation Kit 
64394-025
64394-003
Integrated Pit Lid Hanger  
Installation Kit
64394-026
64394-009
VAULT
Vault Installation Kit/Non-Standard 
Permalog+
®  
Installation Kit
64394-027
64394-008
REMOTE
Remote Wall Mount Box Enclosure Kit
64394-028
64394-028
64394-021
Remote Installation Bracket Kit
64394-029
64394-029
64394-019
* Refer to ORI-P-09 for individual endpoint installation kit components. 