Tools and Materials (customer-supplied)
• 
Precision slotted screwdriver 2 .4 mm (0 .094 inch) blade size
• 
Two 9/16 inch or adjustable wrenches for mounting V-block clamps (standard mounting)
• 
Band-IT®
 
tool (refer t
) and instructions, a 1/2 inch wrench and a hammer for large diameter  
pole mounting
• 
Wrench for 1-1/16 inch gland nut and 1-1/16 inch dome nut
• 
Strap wrench for backhaul antenna
Using the V-block Clamps
The V-block mounting equipment is sized to mount the gateway on a vertical or horizontal pole with outer diameters ranging 
from 1-1/4…2-1/2 inches . For mounting on poles larger than 2-1/2 inches, refer t
 .
1 .  Open the bag of mounting equipment .
2 .  Place two bolts (3/8-16 x 5 inches) through the holes in the top of the gateway mounting backplate (Figure 5) .  
Use the side holes for horizontal installation .
3 .  Place a clamp onto the bolts, as shown below .
4 .  Place a lock washer and nut onto each bolt, as shown below .
OTE:
N
The lock washer and nut nearest the enclosure mounting bracket may be omitted when mounting on smaller 
diameter poles to provide additional clamping distance .
 
Figure 5:   Attach hardware
5 .  Tighten the two nuts with a 9/16-inch or adjustable wrench, so that each lock washer is fully compressed and flat .
6 .  Repeat Steps 2 through 5, attaching a clamp to the bottom of the mounting backplate . Position the gateway on the 
pole and place a clamp on the top bolts .