IDENTIFICATION
The Badger Meter High Resolution Encoder (HRE) is available in two 
versions:
With a potted three-wire flying lead
With three terminal screws
The HRE with glass lens is available factory pre-wired to  
Badger Meter AMR/AMI products, or may be spliced to other devices 
following the instructions below. This version is permanently sealed 
to eliminate the intrusion of moisture, dirt, or other contaminants, 
and is suitable for installation in all environments, including meter 
pits subject to continuous submergence.
The HRE with terminal screws features the same permanent sealing 
of the register's internal elements, but does not provide a moisture 
resistant enclosure. Therefore it is suitable for indoor installation in  
a dry environment only, and is marked as such on the terminal 
screw cover.
Available for all Recordall® Disc, Turbo, Compound, Combo and Fire 
Service Meters and Assemblies, each HRE is clearly identified on 
the face of the dial with an assembly number, unit of measure, and 
meter model.
REQUIRED MATERIAL
62084-001 Field Splice Kit Contents:
(3) 59761-001 Gel-Connectors
(2) 34776-001 Cable Ties
(1) 62085-001 Splice Enclosure
SUGGESTED TOOLS
Screw Driver
59983-001 Gel-Splice Crimping Tool (Flying lead versions only)
59989-001 Coax Stripper
59991-001 Wire Cutting Pliers
59993-001 Wire Stripper
TORX® Driver
Before proceeding with installation, be certain that the meter type 
and size correspond, and that the proper HRE configuration has 
been supplied for the application.
THE HRE SHOULD ONLY BE CONNEC TED TO A BADGER 
METER APPROVED PRODUCT. CONNECTION TO AN 
UNAPPROVED PRODUCT WILL VOID THE HRE WARRANTY.
CONNECTING THE HRE
Your HRE will have a factory installed three-conductor cable (brown) 
for connection to an AMR module.
If the wire is cut or broken and requires a field splice after 
initial installa- tion, connect like color wires to maintain proper 
installation.
To connect to an AMR module, strip approximately 1-1/2" of outer 
insulation sheath from the HRE and AMR module cables using the 
59989-001 Coax Stripping Tool. Use caution in removing the outer 
sheath so that the inner signal wire insulation is not damaged.
Strip the outer sheath
If the outer foil shield remained after removing the insulation 
sheath, unwind the outer foil shield on the cable ends and cut it 
off even with the outer sheath. Then cut the uninsulated shield 
drain wire even with the outer sheath. Inspect the inner signal wire 
insulation to insure it was not damaged; any slice in the insulation 
of the signal wires could result in a short between conductors 
resulting in a tamper condition on the AMR product.
Sheath and outer foil removed
Drain wire cut off
Insert the like color conductors from each cable end into the Gel-
Connector. Inspect that the conductors are through the crimp bar 
and all the way to the end of the Gel-Connector.
Wires to end of gel connector
Wires should be visible through the end
Area to inspect
Area to inspect
HR | E High Resolution Encoder
ENC-UM-00237-EN-01 (June 2013)
Installation Data